The International Building Code refers to the American Society of Civil Engineer requirements for both non-engineered and engineered flood openings. In lieu of these requirements, engineered openings must conform to a performance standard: during a flood with a rate of rise/fall of five feet per hour, the difference between interior and exterior flood water levels in an enclosure using the engineered openings must not be greater than one foot. Openings must be placed such that the bottom of each opening is no more than one foot above the adjacent ground level. The total net open area of all flood openings in the structure must be equal to or greater than one square inch, per square foot of footprint of the enclosed area-though no fewer than two openings, total, which must be located on different walls. Where non-engineered openings are used, each opening must be at least three inches in diameter, and have no screen or other cover that interferes with the transition of water between interior and exterior. It calls for openings in load-bearing foundation walls located below the mapped flood elevation. The American Society of Civil Engineers (ASCE) requirements apply to any structure that is not dry flood-proofed and which is in the mapped flood zone. To qualify as an engineered opening, testing and/or certification by a qualified agency (varying from regulator to regulator, and indicated below where appropriate) is required.Īmerican Society of Civil Engineers definition Engineered openings ignore many of the requirements, depending on the particular regulatory authority. The requirements for non-engineered openings are typically stricter, defining necessary characteristics for aspects ranging from overall size of each opening, to allowable screening or other coverage options, to number and placement of openings.
![asce 24 free download asce 24 free download](https://ars.els-cdn.com/content/image/1-s2.0-S2666790821000999-gr3.jpg)
Most regulatory authorities in the United States that offer requirements for flood openings define two major classes of opening: engineered, and non-engineered. The wet floodproofing technique is required for residential buildings.Įngineered vs. Enclosed areas are permitted under elevated buildings provided that they meet certain use restrictions and construction requirements such as the installation of flood vents to allow for the automatic entry and exit of flood waters. The NFIP Regulations and Building Codes require that any residential building constructed in Flood Zone Type A have the lowest floor, including basements, elevated to or above the Base Flood Elevation (BFE). Various agencies in the United States define necessary characteristics for flood openings.
![asce 24 free download asce 24 free download](https://ars.els-cdn.com/content/image/1-s2.0-S1874548221000731-gr2.jpg)
Building codes usually require the installation of flood openings in the walls of structures located in A-type flood zones recognized by the Federal Emergency Management Agency. In the United States, flood openings are used to provide for the automatic equalization of hydrostatic pressure on either side of a wall. 1.4 International Residential Code (IRC).1.2 American Society of Civil Engineers definition.